Aging Equipment Calibration: Check the Equipment Before Blaming the LEDs
Summary

When aging data looks wrong, check current, temperature, power supply and fixture contact before blaming the LEDs.

What to calibrate

Item Tool
Current Standard ammeter / shunt
Voltage Standard voltmeter
Temperature Standard thermometer / data logger
Time Timer
Fixture contact Contact resistance test

How to calibrate

  • Current: setpoint vs. measured value, record deviation
  • Temperature: sensor vs. standard thermometer
  • Multi-channel: sample each channel and find outliers
  • Label and record after calibration

Common problems

  1. No calibration for a long time, current drifts
  2. Temperature sensor in the wrong position
  3. Only one channel calibrated
  4. Oxidized probes, high contact resistance
  5. Missing calibration records

Maintenance suggestions

  • Daily check of current/temperature display
  • Monthly channel spot checks
  • Calibration every 6–12 months
  • Re-calibrate after replacing probes
  • Keep calibration certificates

Need calibration or maintenance service? Send the equipment model and years in use.