LED Aging Test: Process, Parameters and Judgment
Summary

A practical LED aging test procedure: preparation, loading, parameter setting, inspection, recovery and post-test measurement.

What aging testing is for

Aging (burn-in) testing exposes early failures and long-term degradation. It only makes sense when current, temperature and measurement conditions are controlled and comparable.

Six steps

  1. Preparation — check temperature/humidity, ESD, equipment calibration and record initial values.
  2. Loading — place LEDs in the fixture, confirm polarity and contact, record position numbers.
  3. Parameter setting — set temperature (25/55/85°C), constant current, duration (24/48/168/500/1000h) and lock the settings.
  4. In-process inspection — check current, temperature, smell, noise and dead LEDs at defined intervals.
  5. Unloading and recovery — power down, recover to room temperature (about 2h after high-temperature tests) before measurement.
  6. Post-test measurement — measure luminous flux, color coordinates, VF and IR; compare with initial values and judge.

Typical parameters

Item Typical setting
Current Rated current, constant current
Temperature 25°C / 55°C / 85°C
Duration 24 / 48 / 168 / 500 / 1000 h
Recovery About 2 h at room temperature

Common mistakes

  • Measuring before the sample returns to room temperature
  • Using a non-constant-current power supply
  • Insufficient heat dissipation
  • No initial data for comparison
  • Mixing different test conditions in one batch

Equipment

Aging boards for small batches and R&D; aging racks for batch production with better power margin and heat dissipation. Add a colorimeter or tester for optical and electrical parameters.

Need help defining an aging test plan? Send us the LED package, test items and capacity.

Related Product

View product →

Need a test solution?

Tell us your LED package, test items and daily capacity. Our engineers will recommend a configuration.