Summary
High-voltage LEDs need adequate voltage range, isolation and protection. Low-voltage testers can give wrong data or damage equipment.
Characteristics
- Single LED VF often 6V, 9V, 18V or 36V
- Multiple chips in series or series-parallel
- Higher requirements for withstand voltage, insulation and creepage distance
- Failure modes include open circuit, leakage and breakdown
Check before testing
| Item | Requirement |
|---|---|
| Voltage range | Cover maximum VF with about 20% margin |
| Current | Constant current, matched range |
| Withstand voltage | Fixture and wiring rated for the voltage |
| Insulation | Avoid breakdown |
| Protection | Open/short-circuit protection |
Test precautions
- Start with low current, then increase to rated
- Avoid hot plugging
- Isolate high-voltage and low-voltage signal wiring
- Ensure good contact to avoid arcing
- Do not exceed the reverse-voltage limit when measuring IR
Common mistakes
- Using a 3V range to test an 18V LED
- No open-circuit protection, damaging LEDs
- Fixture not rated for the voltage, causing arcing
- Mixing high- and low-voltage wiring
- Skipping IR measurement
Need a high-voltage LED test solution? Send the VF range, series/parallel structure and current.
Need a test solution?
Tell us your LED package, test items and daily capacity. Our engineers will recommend a configuration.