High-Voltage LED Testing: Do Not Use Low-Voltage Equipment
Summary

High-voltage LEDs need adequate voltage range, isolation and protection. Low-voltage testers can give wrong data or damage equipment.

Characteristics

  • Single LED VF often 6V, 9V, 18V or 36V
  • Multiple chips in series or series-parallel
  • Higher requirements for withstand voltage, insulation and creepage distance
  • Failure modes include open circuit, leakage and breakdown

Check before testing

Item Requirement
Voltage range Cover maximum VF with about 20% margin
Current Constant current, matched range
Withstand voltage Fixture and wiring rated for the voltage
Insulation Avoid breakdown
Protection Open/short-circuit protection

Test precautions

  • Start with low current, then increase to rated
  • Avoid hot plugging
  • Isolate high-voltage and low-voltage signal wiring
  • Ensure good contact to avoid arcing
  • Do not exceed the reverse-voltage limit when measuring IR

Common mistakes

  1. Using a 3V range to test an 18V LED
  2. No open-circuit protection, damaging LEDs
  3. Fixture not rated for the voltage, causing arcing
  4. Mixing high- and low-voltage wiring
  5. Skipping IR measurement

Need a high-voltage LED test solution? Send the VF range, series/parallel structure and current.

Related Product

View product →

Need a test solution?

Tell us your LED package, test items and daily capacity. Our engineers will recommend a configuration.