Summary
Common failure modes after 85°C/85%RH biased testing: encapsulant yellowing, package cracking, corrosion and leakage.
Common failure modes
| Mode | Symptom |
|---|---|
| Encapsulant yellowing | Lumen decay, color shift |
| Package cracking | Leakage, dead LED |
| Lead-frame corrosion | Higher IR, poor contact |
| Wire bond / solder joint | Open circuit, intermittent light |
| Chip leakage | IR over limit, abnormal VF |
Why it happens
- Moisture penetrates the package
- Bias voltage accelerates electrochemical corrosion
- High temperature accelerates encapsulant aging
- Condensation causes short circuits
- Thermal expansion mismatch
How to avoid false judgments
- Dry samples before testing
- Apply bias only after temperature and humidity stabilize
- Recover to room temperature before measurement
- Measure IR and color, not only brightness
- Keep failed samples for cross-section
Common mistakes
- Treating condensation shorts as LED failures
- Insufficient recovery time
- Measuring flux only, not IR
- No initial data
- Chamber not calibrated