85/85 Aging Failure Modes: Why LEDs Fail After Humidity Testing
Summary

Common failure modes after 85°C/85%RH biased testing: encapsulant yellowing, package cracking, corrosion and leakage.

Common failure modes

Mode Symptom
Encapsulant yellowing Lumen decay, color shift
Package cracking Leakage, dead LED
Lead-frame corrosion Higher IR, poor contact
Wire bond / solder joint Open circuit, intermittent light
Chip leakage IR over limit, abnormal VF

Why it happens

  • Moisture penetrates the package
  • Bias voltage accelerates electrochemical corrosion
  • High temperature accelerates encapsulant aging
  • Condensation causes short circuits
  • Thermal expansion mismatch

How to avoid false judgments

  • Dry samples before testing
  • Apply bias only after temperature and humidity stabilize
  • Recover to room temperature before measurement
  • Measure IR and color, not only brightness
  • Keep failed samples for cross-section

Common mistakes

  1. Treating condensation shorts as LED failures
  2. Insufficient recovery time
  3. Measuring flux only, not IR
  4. No initial data
  5. Chamber not calibrated

Need 85/85 testing or failure analysis? Send the package and bias conditions.

Related Product

View product →

Need a test solution?

Tell us your LED package, test items and daily capacity. Our engineers will recommend a configuration.