LED Color Sorting: Process, Parameters and Equipment
Summary

How LED color sorting works: parameters, measurement conditions, binning rules and common errors.

What color sorting measures

Color sorting groups LEDs by luminous flux/brightness, color coordinates, CCT, SDCM and VF under fixed current and stable temperature.

Parameters

Parameter Purpose
Luminous flux / brightness Brightness bins
Color coordinates x,y / u′v′ Color bins
CCT White-light bins
SDCM Color consistency
VF Voltage bins

Measurement conditions

  • Fixed current per datasheet
  • Warm-up until stable
  • Same instrument and measurement distance
  • Stable ambient temperature and no airflow

Process

  1. Verify the incoming lot
  2. Set current and warm-up time
  3. Measure each LED or position
  4. Sort by bin rules
  5. Record and export data
  6. Isolate and re-check abnormal LEDs

Binning rules

  • Brightness bins per customer or industry practice
  • Color regions per customer chart
  • SDCM typically ≤3 steps (per customer)
  • VF bins per datasheet

Define rules before measurement, not after.

Common mistakes

  1. Measuring without warm-up
  2. Mixing instruments or distances
  3. Sorting brightness only, ignoring color
  4. Inconsistent color-region rules
  5. No data records for traceability

Need a color sorting or colorimeter solution? Send the LED type, binning requirements and daily volume.

Related Product

View product →

Need a test solution?

Tell us your LED package, test items and daily capacity. Our engineers will recommend a configuration.