Summary
How LED color sorting works: parameters, measurement conditions, binning rules and common errors.
What color sorting measures
Color sorting groups LEDs by luminous flux/brightness, color coordinates, CCT, SDCM and VF under fixed current and stable temperature.
Parameters
| Parameter | Purpose |
|---|---|
| Luminous flux / brightness | Brightness bins |
| Color coordinates x,y / u′v′ | Color bins |
| CCT | White-light bins |
| SDCM | Color consistency |
| VF | Voltage bins |
Measurement conditions
- Fixed current per datasheet
- Warm-up until stable
- Same instrument and measurement distance
- Stable ambient temperature and no airflow
Process
- Verify the incoming lot
- Set current and warm-up time
- Measure each LED or position
- Sort by bin rules
- Record and export data
- Isolate and re-check abnormal LEDs
Binning rules
- Brightness bins per customer or industry practice
- Color regions per customer chart
- SDCM typically ≤3 steps (per customer)
- VF bins per datasheet
Define rules before measurement, not after.
Common mistakes
- Measuring without warm-up
- Mixing instruments or distances
- Sorting brightness only, ignoring color
- Inconsistent color-region rules
- No data records for traceability
Need a color sorting or colorimeter solution? Send the LED type, binning requirements and daily volume.
Need a test solution?
Tell us your LED package, test items and daily capacity. Our engineers will recommend a configuration.