Summary
A practical incoming inspection report template: lot information, sampling, test items, AQL judgment and records.
What a usable report must contain
- Basic information — supplier, model, lot, quantity, arrival date
- Sampling — plan, sample size, inspector
- Appearance/dimensions — damage, cracks, contamination, pin oxidation
- Electrical — VF, IR
- Optical — flux/brightness, color coordinates (as required)
- Test conditions — current, temperature, warm-up, equipment ID
- Judgment — item and lot (accept/concession/reject)
- Signatures — inspector, reviewer, date
Sampling
- GB/T 2828.1 or internal plan
- Define lot size, inspection level and AQL
- Critical defects: c = 0
- Small lots may be 100% inspected
Template
LED Incoming Inspection Report
Supplier: ______ Model: ______ Lot: ______
Quantity: ______ Arrival: ______ Inspection date: ______
Sampling: GB/T 2828.1, level II, AQL: critical 0.65 / minor 1.5
Sample size: ______ Equipment: ______
Appearance/dimensions: defects ____ Result: Accept / Reject
VF range: ______ Out of spec: ____ Result: Accept / Reject
IR max: ______ Over limit: ____ Result: Accept / Reject
Flux/brightness: ______ Color: ______ Result: Accept / Reject
Lot result: Accept / Concession / Reject
Defect description: ______________________
Inspector: ______ Reviewer: ______ Date: ______
Common mistakes
- No lot number or sampling plan
- Pass/fail only, no measured data
- Test conditions missing
- Same conditions for all packages
- Failed samples not isolated
Need an inspection template or tester? Send the package and lot size.
Need a test solution?
Tell us your LED package, test items and daily capacity. Our engineers will recommend a configuration.