Summary
Why junction temperature matters and how to measure it with the VF method, infrared camera and thermocouple.
Why junction temperature matters
Junction temperature (Tj) is the temperature inside the LED chip, not the case temperature. Higher Tj accelerates lumen decay and shifts brightness, wavelength and VF.
Three common methods
| Method | Use | Note |
|---|---|---|
| Forward-voltage (VF) method | Production / lab | Requires VF-temperature calibration |
| Infrared camera | R&D / failure analysis | Surface only; emissivity correction needed |
| Thermocouple | Rough measurement | Contact resistance affects accuracy |
VF method
- Calibrate VF vs. temperature at a constant current
- Heat the LED to a stable condition
- Switch to a small current and measure VF quickly
- Convert the VF change to junction temperature
- Calculate thermal resistance together with power dissipation
The switch must be fast, otherwise the junction cools before measurement.
Common mistakes
- Treating case temperature as junction temperature
- Poor thermocouple contact
- No emissivity correction for infrared
- Calibration and measurement conditions differ
- Testing one LED and ignoring lot variation