Same LED Lot, Different Brightness After Aging: A Thermal Case
Summary

A practical case showing how uneven fixture contact and heat dissipation cause different junction temperatures and brightness after aging.

The symptom

  • Same lot, same current and same aging time
  • Some LEDs are visibly dimmer after aging
  • VF higher and color shifted on the dimmer parts
  • Results change when the sample is moved to another position

Troubleshooting sequence

  1. Swap positions — does the failure follow the LED or the position?
  2. Measure junction temperature — is the abnormal position hotter?
  3. Check heat path — thermal paste, heat sink and airflow
  4. Measure VF/IR — separate chip issues from contact issues
  5. Microscope / cross-section — solder joint and die attach

Common root causes

  • Uneven probe pressure and contact resistance
  • Thermal paste applied unevenly or dried out
  • Blocked airflow causing local hot spots
  • LED not seated correctly in the fixture
  • Uneven current between channels

What to do

  • Standardize probe pressure and contact
  • Check thermal paste/thermal pads periodically
  • Improve airflow to avoid hot spots
  • Calibrate per-channel current
  • Sample junction temperature for critical lots

Need a thermal or aging consistency solution? Send the package, power and fixture design.