Summary
A practical case showing how uneven fixture contact and heat dissipation cause different junction temperatures and brightness after aging.
The symptom
- Same lot, same current and same aging time
- Some LEDs are visibly dimmer after aging
- VF higher and color shifted on the dimmer parts
- Results change when the sample is moved to another position
Troubleshooting sequence
- Swap positions — does the failure follow the LED or the position?
- Measure junction temperature — is the abnormal position hotter?
- Check heat path — thermal paste, heat sink and airflow
- Measure VF/IR — separate chip issues from contact issues
- Microscope / cross-section — solder joint and die attach
Common root causes
- Uneven probe pressure and contact resistance
- Thermal paste applied unevenly or dried out
- Blocked airflow causing local hot spots
- LED not seated correctly in the fixture
- Uneven current between channels
What to do
- Standardize probe pressure and contact
- Check thermal paste/thermal pads periodically
- Improve airflow to avoid hot spots
- Calibrate per-channel current
- Sample junction temperature for critical lots