LED Lifetime: LM-80 and TM-21 Explained
Summary

What LM-80 measures and how TM-21 projects lifetime from LM-80 data, including common misunderstandings.

LM-80 vs. TM-21

  • LM-80 is a test method: luminous flux maintenance at controlled currents and temperatures over at least 6,000 hours (often 6,000 or 10,000 h).
  • TM-21 is a projection method: it uses LM-80 data to estimate lumen maintenance lifetime (L70/L90).

LM-80 does not give a lifetime by itself; TM-21 produces an estimate, not a measured value.

What to check in an LM-80 report

  1. Test current — does it match your application?
  2. Temperature points — 55/85/105°C coverage
  3. Duration — 6,000 h or 10,000 h
  4. Sample size — typically ≥25 LEDs per temperature
  5. Lumen maintenance data — look at the curve, not only the conclusion
  6. TM-21 projection — note the extrapolation factor and L70/L90

Common misunderstandings

  • Treating an LM-80 report as a lifetime report
  • Ignoring test current and temperature
  • Mixing data from different conditions
  • Extrapolating beyond 6× the test duration
  • Ignoring driver and thermal design

What it means for purchasing

Use LM-80 and TM-21 as reference data, together with your own aging tests and the actual driver/thermal design.

Need aging or lumen maintenance testing? Tell us the LED model and operating conditions.

Related Product

View product →

Need a test solution?

Tell us your LED package, test items and daily capacity. Our engineers will recommend a configuration.