Summary
What LM-80 measures and how TM-21 projects lifetime from LM-80 data, including common misunderstandings.
LM-80 vs. TM-21
- LM-80 is a test method: luminous flux maintenance at controlled currents and temperatures over at least 6,000 hours (often 6,000 or 10,000 h).
- TM-21 is a projection method: it uses LM-80 data to estimate lumen maintenance lifetime (L70/L90).
LM-80 does not give a lifetime by itself; TM-21 produces an estimate, not a measured value.
What to check in an LM-80 report
- Test current — does it match your application?
- Temperature points — 55/85/105°C coverage
- Duration — 6,000 h or 10,000 h
- Sample size — typically ≥25 LEDs per temperature
- Lumen maintenance data — look at the curve, not only the conclusion
- TM-21 projection — note the extrapolation factor and L70/L90
Common misunderstandings
- Treating an LM-80 report as a lifetime report
- Ignoring test current and temperature
- Mixing data from different conditions
- Extrapolating beyond 6× the test duration
- Ignoring driver and thermal design
What it means for purchasing
Use LM-80 and TM-21 as reference data, together with your own aging tests and the actual driver/thermal design.
Need aging or lumen maintenance testing? Tell us the LED model and operating conditions.
Need a test solution?
Tell us your LED package, test items and daily capacity. Our engineers will recommend a configuration.