LED Lumen Decay Test: Conditions, Data and Criteria
Summary

How to run a lumen decay test: fixed current, temperature and measurement conditions, data recording and lumen maintenance criteria.

What lumen decay testing measures

Lumen maintenance is the ratio of luminous flux at a given time to the initial flux. It is used to judge light output degradation and to support lifetime estimates.

Test conditions

Item Requirement
Current Rated current, constant current
Temperature 25°C / 55°C / 85°C
Time points 0 / 24 / 48 / 168 / 500 / 1000 h
Measurement Same current, temperature and warm-up time before and after aging
Recovery Return to room temperature before measurement

Data to record

  • Luminous flux and maintenance ratio
  • VF and IR
  • Color coordinates / CCT
  • Test temperature, current, equipment ID and operator

Typical criteria

Parameter Common criterion
Lumen maintenance ≥95% at 500 h, ≥90% at 1000 h (per customer spec)
Color shift Δu′v′ ≤ 0.005
VF change ≤ ±5%
IR Within datasheet limit

Criteria should be agreed before testing, not after.

Common mistakes

  1. Different measurement conditions before and after aging
  2. No temperature control
  3. Ordinary power supply instead of constant current
  4. Measuring immediately after aging
  5. Testing only one LED