How to Read an LM-80 Report: Six Points for Buyers
Summary

A buyer-oriented guide to reading LM-80 reports: current, temperature points, sample size, duration, lumen data and TM-21.

Six points to check

  1. Test current — does it match your application?
  2. Temperature points — 55/85/105°C coverage
  3. Duration — 6,000 h or 10,000 h
  4. Sample size — typically ≥25 LEDs per temperature
  5. Lumen maintenance data — inspect the curve, not only the conclusion
  6. TM-21 projection — check the extrapolation factor and L70/L90

Common traps

  • Report for an old model or lot
  • Current differs from actual use
  • Only a conclusion page, no raw data
  • Extrapolation beyond 6× the test duration
  • No third-party qualification when required

How to use it

  • Request the complete report before purchase
  • Verify model, lot and conditions
  • Use it as a reference together with your own aging tests
  • Do not treat it as a guaranteed lifetime

Relation to incoming inspection

LM-80 is supplier reliability data; incoming inspection verifies lot consistency. They complement but do not replace each other.

Need LM-80-related aging or testing? Send the LED model and operating conditions.

Related Product

View product →

Need a test solution?

Tell us your LED package, test items and daily capacity. Our engineers will recommend a configuration.